The Green Data Center Blog today pointed me to December's Cover Feature of Computer, the IEEE Computer Society's magazine. In it, authors Luiz André Barroso (distinguished engineer at Google) and Urs Hölzle (senior vice president of operations at Google and a Google Fellow) point out "Energy-proportional designs would enable large energy savings in servers, potentially doubling their efficiency in real-life use. Achieving energy proportionality will require significant improvements in the energy usage profile of every system component, particularly the memory and disk subsystems."
The two are making the case not only for server power management, but are calling on vendors to go a step further, to make computers adapt their consumptive ranges directly to the compute load consumed. This would be highly complementary to consolidation efforts currently underway.
In conclusion, the paper says,
- Servers and desktop computers benefit from much of the energy-efficiency research and development that was initially driven by mobile devices' needs. However, unlike mobile devices, which idle for long periods, servers spend most of their time at moderate utilizations of 10 to 50 percent and exhibit poor efficiency at these levels. Energy-proportional computers would enable large additional energy savings, potentially doubling the efficiency of a typical server. Some CPUs already exhibit reasonably energy-proportional profiles, but most other server components do not.
- We need significant improvements in memory and disk subsystems, as these components are responsible for an increasing fraction of the system energy usage. Developers should make better energy proportionality a primary design objective for future components and systems. To this end, we urge energy-efficiency benchmark developers to report measurements at nonpeak activity levels for a more complete characterization of a system's energy behavior
Among a few scholarly pieces from Google, the report also cites two great references; one, the US EPA's Report to Congress on Data Center Efficiency, and the other is one of many fine works by Jonathan Koomey, "Estimating Total Power Consumption by Servers in the U.S. and the World"
I attended Day #1 of the Gartner Data Center conference here in Las Vegas today - after making the strategic error of being dropped-off at the MGM Grand lobby, and having to walk what must have been 3/4 mile to the conference center...Thomas Bittman opened the AM with a keynote on the Future of Data Center Operations. It had a pretty broad coverage of the state of DC Ops today. He had at least one memorable interjection -- What seemed as a warning to equipment vendors who have strangle-holds over customers... strongly urging customers to reject platform-specific IT technologies. He also predicted the emergence of the "meta-O/S" and the "cloud-O/S" which (I think) is a re-packaging of Gartner's Real Time Infrastructure (RTI) story. And that the meta-O/S had to be platform adn vendor-neutral. But this was the first time that I've heard Gartner pay specific attention to the emergence & legitimac of cloud computing (and the "O/S" to run it).Next, Donna Scott gave an equally broad-ranging talk on IT Operations Management. Again, she conducted her now 5+ year-old survey of IT's biggest pressures. And once again "high rate of change", "cost containment" and "maintaining availability" took top-honors as the largest ulcer-producing pressures facing CIOs. Also true-to-form, she re-iterated that a shared infrastructure (RTI) is inevitable, breaking down the islands of technology in large data centers. There were also some interesting vendor break-out sessions; take for example, a session on managing power and cooling from Emerson Network Power by Greg Ratcliff. The trend here is also toward an intelligent monitoring and infrastructure. He spoke of localized cooling (even within the rack) needed as rack power density increases. There was definitely reference to "adaptive cooling" and "adaptive power" -- again implying that efficiencies in large data centers can only be achieved through better use of technology, rather than throwing raw horsepower at the heat/power problem.Finally, one last surprising (to me) datapoint: the general audience was asked who was using virtualization in production - and 1/2 to 2/3 of the audience raised their hands. This definitely drove-home the point that VMs are (and will be) everywhere. However, I combine this observation with the earlier point that data centers will need a management layer, an "O/S", which is vendor-neutral. At the moment, I don't see any of the existing large vendors stepping up to fill this virtualization managment need any time soon.
I've been reading-up on work that the Green Grid, Uptime Institute and others have been doing to define metrics around data center efficiency. The work is good but in my mind, misses the mark slightly. All of the metrics I've seen thus far are static - That is, they assume some steady-state aspect of the data center... steady compute loads, steady quantity of servers, etc. But that's not how the world works.
Even Detroit knows that autos get different efficiencies based on how & where they're driven... so the metric called "mileage" is actually measured & documented twice -- one for City, one for Highway. Data Centers need something akin to this as well.
Why? Because IT departments operate at greatly different levels; peak (maybe during the day) as well as off-peak (perhaps nights/weekends). Ideally, the data center should know how to adapt to these conditions: re-purposing "live" machines during peak hours; retiring and temporarily shutting-down idle servers during off-peak; removing power conditioning equipment when not needed; turning off specific CRAC units and chillers when not required (i.e. cold days and/or off-peak hours). We need an efficiency metric that indicates how data centers operate Dynamically.
Anyway, here's a quick survey course in what metrics I did find, and what I'd like to see:
The Green Grid on metrics:
- Data Center Infrastructure Efficiency,
DCiE = (IT equipment power)/(total facility power).
This is supposed to be a quick ratio showing how much power gets to servers, versus how much else is consumed by power distribution, cooling, lighting, etc. Driving this ratio up means you have less overhead wasting Watts. This wouldn't be too bad a metric if it was used and monitored 24x7, i.e. peak and off-peak.
- Power Usage Effectiveness,
PUE = 1/DCiE (just the boring reciprocal)
- Data Center Productivity, (a metric to be adopted in the future)
DCP = (useful computing work)/(total facility power)
In theory, this is a great metric: It's like saying "how many MIPS per Watt" can you produce? (BTW, the human brain, the most powerful of all computers, consumes somethling like 25W). Anyway, DCP is a contentious metric... because each computing vendor wants to define "useful computing work" with their own (preferential) way of computing. Frankly, this is most useful to measure efficiency at the server level.
The Uptime Institute
In an excellent paper, the Uptime Institute discusses these in "Four Metrics Define Data Center "Greenness":
- Site Infrastructure Energy Efficiency Ratio:
SI-EER which the Institute is currently working to re-cast in more intuitive and technically accurate terms. I suspect this is much like the Green Grid's DCiE, above - Site Infrastructure Power Overhead Multiplier Which is essentially the same metric as the Green Grid's PUE, above
SI-POM = (data center power consumption at the meter)/(total power consumption at the plug for IT equipment)
- Deployed Hardware Utilization Ratio:
DH-UR = (qty of servers running live applications)/(total number of servers actually deployed)
This speaks to the real-time utilization of hardware, and IMHO is one of the best metrics for a dynamic data center. It points to how many deployed servers are actually doing work, vs. those that are sitting "comatose". A very promising metric if it's used in conjunction with equipment that constantly optimizes how many servers are "on", and shuts down idled servers, constantly minimizing this metric.
- Deployed Hardware Utilization Efficiency
DH-UE = (minimum qty of servers needed to handle peak load)/(total number of servers deployed)
This is another great metric - it speaks to the capital efficiency of hardware - how many need to be provisioned and on the floor, relative to how many are being used actively.
In my ideal world, I'd like to see two things to get us to a "City/Highway" style approach:
- A DH-UR that changes dynamically, constantly being minimized. This implies that only required servers are actually powered-up and active.
- An SI-POM that was always driven toward a constant ratio, regardless of compute demand. Which implies that, as compute demand falls, servers are retired and other support equipment (power handling, cooling) also shuts down, keeping the efficiency ratio balanced.
I look forward to conversations with the Green Grid, Uptime Institute and EPA to consider these tweaks to their already fine work.
I felt the need to share the following conversation I recently had with the VP of Enterprise Operations for a major healthcare provider. On one hand, the conversation sounded like every stereotype I've heard in trade rags... except it's true. So read this, but be sure to get to the punch line at the end.
He's been in his job for 18 months, and is just now seeming to get his hand around turning the battleship. Which, I might add, "owns one of every imaginable platform and software type" and has perhaps 3,000+ apps on 12,000-15,000 servers, maybe 30%-40% is development. He's got lots of AIX and lots of Sun, but ultimately a mix of other vendors too.
When asked exactly what he owns, he says he doesn't really know... but they're planning a CMDB project soon. Also, they're quickly running out of data center space, and are pushing 95% of maximum UPS power in most locations. He's thrown-down the gauntlet and halted all new server purchases -- in favor of initiating a virtualization project (which, I might add, is getting upwards of 20:1 consolidation, although he knows that high ratio won't last). He's a risk-taker because he has to be.
So I asked him point-blank, what does he need to make this work. Without a flinch (or a smile) he said "Process and Automation." Process, a la ITIL, and automation -- both of the Run-Book style, as well as the operational style. " If I could have the automation vision that IBM was hawking a few years ago, I'd be thrilled. But it's still vapor".
The good news is that he's closely teamed with his Facilities manager to help him cope with power, real estate and cooling. The bad news is that the Facilities guy is also at wit's-end.
The punchline: This real-life vignette tells me that the traditional IT model is really broken. How come IT -- with all of its computers -- is actually the least automated and efficient arm of the company? I recently read a report from the Uptime Institute which talked about the Economic Meltdown of Moore's Law -- literally, for every $1 of compute asset, it currently costs $1.80 operate it; by 2009, electricity alone will cost triple ($3) what the box cost. What's wrong with this picture?
I know that my VP friend is not alone. But when will the treadmill of IT-being-slave-to-the-hardware end? I'd like to think that automation, active asset management, and the drive toward greater environmental efficiency will begin to influence vendors and managers alike.
With The announcement of Active Power Management, and now the Cassatt Active Response product line, I hope that data center operations will now nudge a little closer to the 21st century.
Here's analogy #1: You're driving and come to a red light, you stop the car but the engine keeps running. It's wasteful and inefficient, but because it's generally considered too inconvenient to start
& stop your engine every time you hit a red light, nobody does it. Enter the Prius: Come to a red light, and the engine automatically stops; hit the accelerator, and it starts again. Simple. Automatic. Efficient.
That's the analogy Cassatt is bringing to servers -- if they sit idle, even for an hour a day, they're automatically shut off and re-started when they're needed. For production environments, this might only apply to a few scale-out architectures that are provisioned for busy times-of-day, but for Development/Test, there are *always* machines that go unused for periods of time. Cassatt's Active Power Management takes care of this automatically. Simple. Automatic. Efficient.
Don't just believe me. On Aug. 2, the EPA published a Report to Congress on Server and Data Center Efficiency. A core tenet in the report states "implement Power Management on 100% of applicable servers" was a core aspect to "improved operation" of US data centers.
Oh - and here's analogy #2: (and believe-it-or-not, it's from Detroit as well as Japan): It's called Cylinder Shutdown. Turns out that when you literally don't need all the engine's horsepower, cylinders within the engine are dynamically shut down. Check out the future Northstar XV12 Caddy engine, as well the engine in the 2008 Honda Accord.
Turns out, Cassatt technology can do this with IT Servers/blades as well! If you have a farm of servers and a few are sitting idle, they're turned off and kept as "bare metal" until some application needs their horsepower. Then they're dynamically re-purposed for whatever application is needed. That's the ultimate in capital efficiency.
Can this really work? With customers we've spoken to -- some with development environments pushing 4,000 servers -- actively controlling server power & repurposing can save nearly 50% (that's fifty) of operational costs.
Think of all the cars idling at this very moment, and the amount of fuel they're burning. Now, think of all of the servers in your data centers & labs just sitting there waiting to do something. And think of all the Watts they're chewing.
I attended and presented at TelaData's Data Center "Convergence" conference yesterday, and had the opportunity to chat with a number of Facilities and IT Operations managers for really big companies. Over 300 folks were at the event, and I bet 2/3 of them were facilities managers looking for an edge to improve the efficiency (and reduce the cost) of building/maintaining large data centers.
Bob Brown, TelaData's CEO offered that the theme of "convergence" applied to 3 areas:
- Technology Convergence as it applies to voice, video & data all converging to a IP-based standards, and what the implications are on data center build-out, power, cabling, etc.
- Organization Convergence - the need/requirement that IT and Facilities cooperate and drive new efficiencies; without this cooperation, breakthrough efficiencies and cost reductions just aren't possible
- Automation convergence, e.g. building/facilities automation standards (like BACnet) interoperating with IT automation (power control, distribution)
One of the highlights was an end-of-day panel with Robert Aldrich (Cisco - Green Data Center solutions), Bill Weihl (Google's "Energy Czar"), and Dean Nelson (Sun's Global lab & data center services person). The panel was congenial, but it was clear that the companies approach "greenness" from slightly different perspectives:
- Google made it clear that all employees are encouraged to look at Total Cost of Ownership for every project they pursue; they encourage tradeoffs from everyone, esp. between Facilities, operations and IT. It's a numbers game, which benefits the company overall.
- Cisco operates huge data centers as well - they're also numerically driven, and seem focussed on deriving metrics and standards around energy use - before they implement new programs/policies
- Sun also drove home the need for IT & Facilities to interact (Dean brought his Facilities counterpart along) and really emphasized that one of the massive benefits of efficient IT is to "give back" real estate to the company. Real estate is the 2nd largest cost to a company (next to payroll) and this has made a huge impact on Sun's margin and bottom line.
A number of talks on the "energy efficiency" track (including mine) dealt with power control at the server level. During our presentations, Cassatt, Server Technology, PowerAssure and VMware all alluded to various approaches to actively managing server power status. Server Tech took a clearly Facilities-minded approach to "Load Shedding" in emergency conditions; PowerAssure takes a managed-services approach, and VMware spoke to future product capabilities. Cassatt (from my biased perspective) had the best holistic and cross-platform story for actively managing server power status across an enterprise.
What was clear from conversations with folks who attended was that there still a rift between facilities managers and IT. For there to be any meaningful progress in data center efficiency, there had to be shared corporate and economic goals for both. And this had to start at the CFO level (for example).
Two more companies I've recently come across that will help accelerate this model: RightScale, essentially brokers AWS infrastructure, while providing a easier-to-use "dashboard, and FlexiScale, a UK-based company, that's trying to take-on Amazon's web services at its own game. (I guess you need to have the word "scale" in your name nowadays...)
- RightScale provides a platform and consulting services that enable companies to create scalable web solutions running on Amazon Web Services (AWS) that are reliable, easy to manage, and cost less. The RightScale dashboard saves time in maintaining, managing and monitoring all AWS activities, while RightGrid coordinates the auto-scaling of servers according to usage load. The RightImage library provides pre-built installation templates for common software stacks, and RightScale DeltaSets make it easy to customize and manage modifications to machine images. Together with Amazon Elastic Compute CloudAmazon Simple Storage Service (S3) and Amazon Simple Queue Service (SQS) — RightScale enables a next-generation platform for deploying highly scalable web applications.
- FlexiScale's claims:
- Provisioning & Scalability:Additional servers can be launched and load-balanced in <1 style="font-weight: bold;">
- Flexibility:OS agnostic - we support MS Server and all common versions of Linux; Clone a server image and re-use for another test or production server; Policy engine based load-balancing between physical servers
- Self-service via Control Panel or API:Provisioning of Virtual Dedicated Servers; Start, stop and delete Virtual Dedicated Servers; Resize memory and storage
- Quality of Service: Fully monitored system - network, storage and servers; Fully automated HW recovery;Flexible snapshot based backups;Secure - each customer has their own VLAN and their own virtual disks
- Pricing: No subscription fees and no minimum term contract;Simple to understand utility pay-as-you-go pricing model with no catches;Billing module that lets customers see transparently what resources they have been using
I'm sure we'll be seeing more competitors like these in the coming months.